Spesifikasi-BEKALAN KUASA CCTV 9 SALURAN
| Model | HWTV-120-12-9 | HWTV-150-12-9 | |
| INPUT | Julat VOLTAN | 90~130VAC atau 170~260VAC | |
| Julat KEKERAPAN | 47~63Hz | ||
| OUTPUT | KUASA BERKATA | 120W | 150W |
| VOLT | 12V | 12V | |
| SEMASA | 10A 1000mA/SALURAN | 12.5A 1000mA/SALURAN | |
| JENIS FIUS | Fius haba seramik | ||
| PERLINDUNGAN | LEBIH VOLTAN | Jenis perlindungan: Matikan voltan o/p, pengapit dengan diod zener | |
| LEBIH BEBAN | 105~150% kuasa keluaran undian | ||
| LEBIH SUHU | Jenis perlindungan: Matikan voltan o/p, hidupkan semula untuk pulih | ||
| PERSEKITARAN | TEMPAT BEKERJA | -20~+60℃(Rujuk kepada“Lengkung Derating”) | |
| KELEMBAPAN BEKERJA | 20-90% RH bukan konderasi | ||
| KELEMBAPAN SUHU PENYIMPANAN | -20~+85℃, 10~95%RH | ||
| TRMP COEFICIENT | ±0.03%/℃(0~45℃) | ||
| KESELAMATAN&EMC | STANDARD KESELAMATAN | Pematuhan kepada EN61347, IEC60950, EN60950-1:2011+A2:2013 | |
| TAHAN VOLTAN | I/PO/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
| RINTANGAN PENGASINGAN | I/PO/P, I/P-FG, O/P-FG:100M 0hms/500VDC/25℃/70%RH | ||
| EMC | Pematuhan kepada EN55032:2015;EN61000-3-2:2014; EN61000-3-3:2013;EN55024:2010/A1:2015 | ||
| LAIN-LAIN | DIMENSI(L*W*H) | 235*208*53 | 235*208*53 |
Spesifikasi-BEKALAN KUASA CCTV 18 SALURAN
| Model | HWTV-150-12-18 | HWTV-250-12-18 | HWTV-350-12-18 | |
| INPUT | Julat VOLTAN | 90~130VAC atau 170~260VDC | ||
| Julat KEKERAPAN | 47~63Hz | |||
| OUTPUT | KUASA BERKATA | 150W | 250W | 350W |
| VOLT | 12V | 12V | 12V | |
| SEMASA | 12.5A 1000mA/SALURAN | 20A 1000mA/SALURAN | 30A 1000mA/SALURAN | |
| JENIS FIUS | Fius haba seramik | |||
| PERLINDUNGAN | LEBIH VOLTAN | Jenis perlindungan: Matikan voltan o/p, pengapit dengan diod zener | ||
| LEBIH BEBAN | 105~150% kuasa keluaran undian | |||
| LEBIH SUHU | Jenis perlindungan: Matikan voltan o/p, hidupkan semula untuk pulih | |||
| PERSEKITARAN | TEMPAT BEKERJA | -20~+60℃(Rujuk kepada“Lengkung Derating”) | ||
| KELEMBAPAN BEKERJA | 20-90% RH bukan konderasi | |||
| KELEMBAPAN SUHU PENYIMPANAN | -20~+85℃, 10~95%RH | |||
| TRMP COEFICIENT | ±0.03%/℃(0~45℃) | |||
| KESELAMATAN&EMC | STANDARD KESELAMATAN | Pematuhan kepada EN61347, IEC60950, EN60950-1:2011+A2:2013 | ||
| TAHAN VOLTAN | I/PO/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
| RINTANGAN PENGASINGAN | I/PO/P, I/P-FG, O/P-FG:100M 0hms/500VDC/25℃/70%RH | |||
| EMC | Pematuhan kepada EN55032:2015;EN61000-3-2:2014; EN61000-3-3:2013;EN55024:2010/A1:2015 | |||
| LAIN-LAIN | DIMENSI (L*W*H) | 315*215*63 | 315*215*63 | 315*215*63 |