BY1-12.5-XXX/1 (s) 75 150 275 320 385 440 | ||||||||
IEC Elektrik | ||||||||
Voltan Nominalac (50/60Hz) | U₀/un | 60v | 120v | 230v | 230v | 230v | 400v | |
Voltan Operasi Berterusan Maksimum (AC) | Ue | 75v | 150v | 275v | 320v | 385v | 440v | |
Arus pelepasan nominal (8/20μs) | In | 20ka | 20ka | 20ka | 20ka | 10ka | 10ka | |
Arus pelepasan maksimum (8/20μs) | lmax | 50ka | 50ka | 50ka | 50ka | 50ka | 50ka | |
Semasa pelepasan impuls (10/350μs) | lemas | 12.5ka | 12.5ka | 12.5ka | 12.5ka | 10ka | 10ka | |
Tenaga tertentu | W/r | 39kj/q | 39KJ/Ω | 39KJ/Ω | 39KJ/Ω | 25 kJ/Ω | 25kj/Ω | |
Caj | Q | 6.25As | 6.25As | 6.25As | 6.25As | 5As | 5As | |
Tahap perlindungan voltan | Up | 700v | 1000V | 1500v | 1600v | 1800v | 2000v | |
Masa tindak balas | tA | <25 ns | ||||||
Fuse Back-Up (Max) | 315A/250AGG | |||||||
Penarafan Semasa Litar Pendek (AC) | lsccr | 25 ka/50 ka | ||||||
Tov menahan 5s | UT | 114v | 180 | 335v | 335v | 335v | 580v | |
UT | 180v | 230v | 440v | 440v | 440v | 765v | ||
TOV 120min | Mod | Bertahan | Selamat gagal | Selamat gagal | Selamat gagal | Selamat gagal | Selamat gagal | |
Bilangan pelabuhan | 1 | |||||||
Ulelektrik | ||||||||
Voltan Operasi Berterusan Maksimum (AC) | MCOV | 75v | 150v | 275v | 320v | 385v | 440v | |
Penarafan perlindungan voltan | Vpr | 330v | 600V | 900V | 1200v | 1350v | 1500v | |
Arus pelepasan nominal (8/20 μs) | I。 | 20ka | 20ka | 20ka | 20ka | 20ka | 20ka | |
Penarafan Semasa Litar Pendek (AC) | SCCR | 100ka | 200ka | 150ka | 150ka | 150ka | 200ka | |
Mekanikal & Alam Sekitar | ||||||||
Julat suhu operasi TA | -40F hingga+158F [-40 ℃ hingga+70 ℃] | |||||||
Kelembapan operasi yang dibenarkan RH | 5%... 95% | |||||||
Tekanan dan ketinggian atmosfera | 80K PA ... 106K PA/-500m..2000 m | |||||||
Tork skru terminal mmax | 39.9 IBF · Dalam [4.5 nm] | |||||||
Seksyen silang konduktor (max) | 2AWG (pepejal, terkandas)/4 AWG (fleksibel) 35mm² (pepejal, terkandas)/25mm² (fleksibel) | |||||||
Pemasangan | Rail Din 35mm, EN 60715 | |||||||
Tahap perlindungan | IP20 (terbina dalam) | |||||||
Bahan perumahan | Thermoplastic: Pemadaman Ijazah UL94 V-0 | |||||||
Perlindungan terma | Ya | |||||||
Petunjuk keadaan/kesalahan operasi | Green OK/Kecacatan Merah | |||||||
Kenalan Jauh (RC) | Pilihan | |||||||
Kapasiti pensuisan RC | AC: 250V/0.5A; DC: 250V/0.1A; 125V/0.2A; 75V/0.5A | |||||||
Seksyen Salib Konduktor RC (MAX) | 16AWG (pepejal) /1.5mm² (pepejal) |