IEC Elektrik
| Volum AC Nominal (50/60Hz) | 120V | 230V | 230V | ||
| Voltan Operasi Berterusan Maksimum (AC) | (LN) | Uc | 150V | 275V | 320V |
| (N-PE) | Uc | 255V | 255V | 255V | |
| Arus Pelepasan Nomina (8/20)μs) | (LN)/(N-PE) | In | 20 kA/25KA | ||
| Arus Pelepasan Maksimum (8/20μs) | (LN)/(N-PE) | lmaksimum | 50kA/100KA | ||
| Arus Pelepasan Impuls (10/350)μs) | (LN)/(N-PE) | limp | 12.5 kA/50KA | ||
| Tenaga Tertentu | (LN)/(N-PE) | W/R | 39kJ/Ω/625KJ/Ω | ||
| Caj | (LN)/(N-PE) | Q | 6As/12.5As | ||
| Tahap Perlindungan Voltan | (LN)/(N-PE) | Up | 1000V/1500V 1500V/1500V 1600V/1500V/ | ||
| Ikuti Penilaian Gangguan Semasa | (N-PE) | I | 100ARMS | ||
| Masa Respons | (LN)/(N-PE) | tA | <25 ns/<100ns | ||
| Fius Sandaran (maks) | 315A/250A gG | ||||
| Penarafan Arus Litar Pintas (AC) | (LN) | lscCR | 25kA/50 kA | ||
| TOV Menahan 5s | (LN) | UT | 180V | 335V | 335V |
| TOV 120min | (LN) | UT | 230V | 440V | 440V |
| Mod | Gagal Selamat | Gagal Selamat | Gagal Selamat | ||
| TOV Menahan 200s | (N-PE) | UT | 1200V | ||
| Bilangan Pelabuhan | 1 | ||||
UL Electrical
| Voltan Operasi Berterusan Maksimum (AC) | (LN)/(N-PE) | MCOV | 150V/255V | 275V/255V | 320V/255V |
| Penilaian Perlindungan Voltan | (LN)/(N-PE) | VPR | 600V/1200V | 900V/1200V | 1200V/1200V |
| Arus Pelepasan Nominal (8/20μs) | (LN)/(-PE) | In | 20KA/20KA | 20KA/20KA | 20KA/20KA |
| Penarafan Arus Litar Pintas (AC) | (LN) | SCCR | 150KA | 150KA | 150KA |
Mekanikal & Alam Sekitar
| Julat Suhu Operasi | Ta | -40 F hingga +158F[-40℃hingga+70℃I |
| Kelembapan Operasi yang Dibenarkan | RH | 5%…95% |
| Tekanan atmosfera dan ketinggian | 80k Pa...106k Pa/-500m...2000m | |
| Tork Skru Terminal | Mmax | 39.9Ibf-in [4.5 Nm] |
| Keratan Rentas Konduktor (maks) | 2AWG (Pepejal, Terdampar)/4AWG (Fleksibel) | |
| 35mm²(Pepejal, Terdampar)/25 mm²(Fleksibel) | ||
| Pemasangan | Rel DIN 35 mm.EN 60715 | |
| Tahap Perlindungan | IP 20 (terbina dalam) | |
| Bahan Perumahan | Termoplastik: Darjah Pemadaman UL94V-0 | |
| Perlindungan Terma | Ya | |
| Petunjuk Keadaan/Kerosakan Operasi | Hijau ok/Merah kecacatan | |
| Kenalan Jauh (RC) | Pilihan | |
| Kapasiti Pensuisan RC | AC:250V /0.5 ABC:250V/0.1 A:125V/0.2 A;75V/0.5A | |
| Keratan Rentas Konduktor RC (maks) | 16AWG (Pepejal)/1.5mm²(Dijual) |
Maklumat Pesanan
| Pesanan Kod | 150 | 275 | 320 |
| BY1-12.5-XXX/3+1 | 1215033 | 1227533 | 1232033 |
| BY1-12.5-XXX/3S+1 (dengankenalan jauh) | 1215034 | 1227534 | 1232034 |
| BY1-12.5-XXX/0 (modul ganti) | 1215001 | 1227501 | 1232001 |
| BY1-12.5-NPE/0 (modul ganti) | 1255002 | 1225502 | 1225502 |
Legenda
Garisan L
N Neutral
Bumi Pelindung PE
Kenalan Isyarat S Pilihan
| BY1-12.5-XXX/3(S)+1 | 150 | 275 | 320 |
| Dimensi Unit Tunggal DIN 43880 | 1 CTN | ||
| Dimensi Pembungkusan (T×L×P) | [200×230×330mm] | ||
| Kuantiti Pesanan Minimum | 16Unit | ||
| BY1-12.5-XXX/0 | 150 | 275 | 320 |
| BY1-12.5-NPE/0 | 50 | ||
| Dimensi Unit Tunggal DIN 43880 | 1 CTN | ||
| Dimensi Pembungkusan (T×L×P) | [200×230×330mm] | ||
| Kuantiti Pesanan Minimum | 64Unit | ||